站内搜索
|
详细信息 Product Name: FM Certificated Temperature Sensitive Cable Model NO.: MS1000 Material: metal Certification: FM, UL,Ce EMC, Ce LVD, GOST-R,Eac, Cccf Trademark: GQ Transport Package: Standard Export Packing Specification: FM Origin: China Product Description FM Proved Digital Type Linear Heat Detectors1. Application scopeCompared with other kinds of detectors. MS1000 digital linear heat detector provides a very-early alarm detecting function to the protected environment. The detector can be known as an intelligent "switch" type detector. The polymers between the two conductors will break down at specific fixed temperature allowing the conductors contact, the shot circuit will initiate the alarm. The detectors has a continuous sensitivity. The sensitivity of linear heat detector will not be influenced by the environment temperature changing and the length of detection cable using. It does not need to be adjusted and compensation. The detector can transfer both alarm and fault signals to control panels normally with DC24V or without DC24V. 2. ClassificationConventional typeThis type of Linear heat detection cable is the most widely indoor used with strong stabilityCR/OD TypeCR/OD type not only has good UV resistance and good weather resistance, strongly recommended for outdoor using even under bad weather conditions, but also with high performance of acid resistant, alkali-resistant, salt spray resistant.EP TypeExplosion proof type. Two main application environments: harsh EMI environment and explosive hazardous environment. The outer jacket of this type is protected by woven metal mesh with good performance of anti-EMI and eliminating the surface static of the linear heat detection cable. We can use this type linear heat detection cable in explosive hazardous environment with safety fence. During the installation, please make grounding connection of the woven metal mesh. Used in harsh EMI environment, single end grounding connection or double ends grounding connection should be specified after analysis of the interference sources.3. Features and benefitsIndustrial safety design.Electrical interface with low power consumption design.Real-time monitoring.Working with DC24V supply or without DC24V supply.Fast response time.No alarm temperature compersation needed.Compatible to any kind fire alarm system.Plenty levels of alarm temperatures: from 60ºCto 180ºC4. Technical parameter1Operating Voltage: DC24V2Allowed Voltage Range: DC16V-DC 28V3Standby Current:≤20 mA4Alarm Current: ≤30 mA5Fault Current: ≤25 mA6Maximum relative humidity for long term use: 90%-98%7IP degree: IP 668Alarm temperatures range: 68ºC, 88ºC, 105ºC, 138ºC, 180ºCControl Unit and EOL BoxMS1000-I Control UnitControl unit MS1000-I is used for MS1000,MS1000-CR-OD and MS1000-EP digital type linear heat detection cable. MS1000 is a digital type linear heat detection cable with comparatively simple output signal, the control unit and EOL box are easy to install and operate.Techical parametersOperating voltage: 24VDCAllowed voltage range: 16VDC-28VDCOperateing current: Standby current:≤ 20mA Fire current:≤ 30mA Faultcurrent:≤ 25mAOperating environment:temperature: -45ºC- +60ºCRelative humidity: 95%IP rating: IP66Dimensions: 90mm×85mm×52mm (L×W×H)MS1000-P terminal Unit (EOL box)EOL Box for MS1000, MS1000-CR/OD and MS1000-EP digital linear heat detection cable.Techical parametersOperating voltage: No electronicsOperating environment:temperature: -45ºC- +60ºCRelative humidity: 95%IP rating: IP66Dimensions: 90mm×85mm×52mm (L×W×H)MS1000-L Control Unit and LocatorControl unit MS1000-L is a controlling device to monitor the temperature change of sensor cable and connected to mainframe of intelligent fire alarming control panel.MS1000-L performs continuous monitoring over fire alarm and open circuit of monitored area as well as distance from fire alarm position. These alarming signals are shown on the LCD and indicators of MS1000-L.Since fire alarm has locking function, MS1000-L must be disconnected to power and reset after ALARM. While fault function could automatically reset, it means that after the clearing fault, the fault signal of MS1000-L is automatically cleared.FeaturesPlastic shell: chemical resistance, aging resistance and impact resistance.IP rating: IP66With LCD, various alarming information could be shownThe detector has high ability of interruption resistance adopting fine grounding measurement, isolation test and software interruption resistance technique. It is able to apply in places with high electromagnetic field interruption.Techical parametersDetector type: Linear heat detector MS1000Operating voltage: DC 24VAllowed voltage range: DC 16V-DC 28VOperateing current: Standby current:≤ 60mA alarm current:≤ 80mAAlarming reset: disconnection resetOperating environment:temperature: -10ºC- +50ºCRelative humidity: ≤95%, no condensationPositioning accuracy: 10m or no longer than 5% of full length (under 25 ºC environment)Application length: no longer than 1,000 metersOuter shell protection class: IP66
|