Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Kunming Gen Qian Commercial Co., Ltd.  

Electrical & Electronics,Industrial Equipment & Components,Manufacturing & Processing Machinery,Security & Protection,Service

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Robert. Woolf
  • 电话:86-13888198985
  • 传真:86-871-63376686
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > 2-IR+UV Explosion Proof Flame Detector Fire Alarm System
2-IR+UV Explosion Proof Flame Detector Fire Alarm System
单价 $360.00 / Piece对比
询价 暂无
浏览 72
发货 Chinayunnankunming
库存 10000Piece
过期 长期有效
更新 2020-09-15 15:49
 
详细信息
Product Name: 2-IR+UV Explosion Proof Flame Detector Fire Alarm System Model NO.: JTG-ZF-C34/JTGB-UF-C35Ex Infrared Sensor Installation: Embedded Wall Infrared Sensor Probe Type: Infrared Temperature Sensor Anti-Theft Alarm System-Wide: Surface Control Alarm Detectors Anti-Theft Alarm System Type: Infrared Detectors Type: Flame Detector Flame Detector: UV+IR Sensor Certification: Sil2, Cccf, CNAS, Ukas, Mc, ILAC-MRA Trademark: GQ Transport Package: Standard Export Packing Specification: GB Origin: China Product Description JTG-ZF-C34/JTGB-UF-C35Ex Point Type UV & 2-IR Flame DetectorSummaryJTG-ZF-C34/JTGB-UF-C35Ex point type UV & IR flame detector (hereinafter referred to detector) adopt flame multispectral signal acquisition method/full frequency wave analysis technology, it avoids the weaknesses to interference of traditional detectors. The detection environment is monitored by increasing slope signal detection technology (PAM), which improves the stability and sustainability of the detector. It ensures that the detector can quickly identify and detect fire while minimizing false alarm. The detector is suitable for all kinds of places, such as oil depot, wine depot, aircraft hangar, chemical equipment site, military equipment site, liquefied gas station, power station, tunnel, etc. With high anti-interference ability, can work well in indoor or outdoor environment. The detector adopts six-wire connection style (two power lines, two fire touch spot lines, two fault touch spot lines), In case of alarm, the fire touch spot changes from normally open to normally closed. In case of fault alarm, the fault touch spot changes from normally closed to normally open. It can be connected with the fire alarm system of any manufacturTechnical ParameterSpectral response:190~260nm,1.0~1.7 um,2.1~3.2um .Response time:5~10s Monitoring angle:≤100°Working voltage: DC24V Static operating current: 45mA Alarm status current: 55mASensitivity: I class ~ class III, I class: 0-25m within the scope of the probe must be reported to the fire.II class: 0-17 m within the scope of the probe must be reported to the fire.III level: 0-12 m within the scope of the probe must be reported to the fire.Protection grade: IP66 Environment temperature: -10 ~ +55ºC Relative humidity: ≤93%RH(45±2ºC)Installation Angle: rotation Angle: 360°, elevation Angle: 90°Exd II CT6 Gb; Ex tD A21 IP66 T80ºC. Cable outlet thread: npt1/2 "nut explosion-proof hose is connected with outlet screw.Product size: Φ60×150mm.Status IndicatorGreen: work indicator light, on when normal, internal device failure report green light does not work.Red: alarm indicator, normally off, often on fire.Power outages resetOutput modelFire relay: normally open, close when alarming.Fault relay: normally closed, disconnected in case of faultTouch spot capacity: 3A /220VAC 3A /30VDCUse and MaintenanceWiring:The wiring is shown in the picture. The red and black wires are connected to the positive and negative electrodes of the DC24V power supply.The yellow and white line is the contact output of the alarm relay, which closes when alarming.The green and blue line is the output of the fault relay, which is fault relay output, normally closed, fault disconnect.If module has terminal resistance, connect blue and green lines, yellow and white lines and terminal resistance, Resistance should be installed as close as possible to the detector. It is not recommended to install resistors near modules.RedDC: +24VConnect the controller to the power supplyDC24VBlackDC: -24VWhiteFire relay touch spot output, dry contact normally open, closed in case of fire.Connect the alarm module signal endYellowBlueFault relay touch spot output, dry contact normal closure, fault disconnect.After connecting the terminal resistance in series, it is connected to the signal end of the alarm module or to the module return route in series.GreenInstallation RequirementOverlooking installation: Depression angle <45°Installation distance:The protection distance of detectors in oil sites is 3m ~ 5m. The protective space of chemical sites is 5m ~ 7m. The protection distance of smelting site is 7m ~ 10m. The protection spacing of power sites is 2m ~ 10m.There should be no obstacles blocking the line of sight of the detector in the fire area. If the obstacles cannot be avoided, the number of detectors should be considered to achieve no-dead Angle detection.Detector shell should be ground.